| Main Technical Parameters: | ||||||||||||||||||
|
||||||||||||||||||
|
Design Reference Suggestions: 1. Recommended design parameter values: aeration rate 3 m³/m·h, oxygen utilization rate 12%. 2. The distance from the hose to the bottom of the tank is generally 300-500 mm, with a hose spacing of 500 mm. This can be adjusted based on water quality, removal load, and oxygen demand. 3. Within a certain range, multiple aeration hoses (generally no more than 10) can be connected to the same air distribution pipe as a group, controlled by one valve. To ensure uniform air supply for all hoses in the group, consider increasing the diameter of the air distribution pipe appropriately. 4. When using aeration hoses in activated sludge processes, especially in Sequencing Batch Reactor (SBR) treatment systems, it is recommended to include sludge discharge measures in the design to allow for the removal of sludge from the pipes when necessary. |